Buttresses¶
CALCULATION OF WALLS IN THE PRESENCE OF BUTTRESSES
The case of buttress walls requires the insertion of geometric data, i.e. thickness and longitudinal interaxis. The buttress can be placed inside (ground side) or outside.
The height of the buttress is assumed equal to the height of the wall itself, while the base is placed equal to the length of the shelf of upstream foundation, for internal buttresses, downstream, for external ones.
The calculation of the thrust on the wall is independent of the presence of the additional element and is carried out with the same procedure as for the corbel wall.
The presence of the buttress has an effect, with the weight force, both in terms of stress on the shelf in elevation, and in the global checks to tipping, limit load and sliding.
The buttress weight is calculated with the unit weight of the wall material and the same partial factor as the self-weight of the wall; in seismic combinations its horizontal inertia force is added.
Verification of the section in c.a. and armor calculation
External buttresses are calculated as inverted T-shaped cantilevers (buttress + collaborating stem) per spacing, with checks for bending with axial force, shear, flange-web shear, buckling of the free edge and serviceability; the stem between two buttresses is calculated as a plate and the buttress reinforcement is designed by the program. Internal buttresses add weight but do not contribute to the strength: the stem is checked as a cantilever without buttresses. The method is described in Buttress design.
Previous method
In previous versions the T-section was replaced by a 1 m wide rectangular section with the same moment of inertia (equivalent thickness). This method has been replaced: the reasons are explained in Buttress design.