What checks does the programme perform on the tie-rods?

The programme provides the factor of safety as the ratio between the resistance of the tendon (minimum of the three failure mechanisms: yielding of the reinforcement, bulb-soil displacement, reinforcement-mortar displacement) and its reaction, calculated according to the type chosen: active tendon, passive tendon.
A minimum length of the free section must also be defined, so that the tendons fulfil their static function of supporting the wall, the bulb should be completely outside the active thrust wedge. Assuming that the thrust wedge is bounded by a line inclined to the horizontal by 45+φ/2, this line should be shifted upwards by h/3 where h represents the excavation height. The minimum value of the free length is thus defined.

Why does SPW change the length of the bulkhead? I would need to check a known penetration depth

It is possible to perform a verification calculation on a known penetration depth.
For this purpose, the FEM analysis method must be selected and the general FEM data set as specified below:
Automatic calculation of the penetration depth: No;
Initial penetration depth: coincides with the penetration depth to be verified;
Increase of the penetration depth: zero. Select the Apply command and carry out the calculation.

Are the default combinations sufficient to perform a bulkhead calculation?

The default combinations are the minimum static combinations required by the standard, the seismic combination must be added: go to the calculation window, right-click on the construction phase and choose ‘New Seismic’, assign the seismic coefficients to this combination only.
The combinations, the two default ones and the seismic combination, are the minimum ones required by the standard.

Does the free length of the tie rod affect the calculation?

Yes, the free length contributes to characterising the stiffness of the tie rod.

In the presence of struts/tirants, how are the design stresses of the contrast beam between two consecutive pins/tirants determined?

A possible dimensioning moment can be the product of the maximum reaction of the point/tirant by the half-distance in the horizontal plane of two consecutive points/tirants (possibly amplified with a coeff. of e.g. 1.5).
A possible dimensioning cutoff for each of the two calculation directions can be given by the maximum reaction of the possibly amplified point/tirant.

Does the software allow metal sheet piles (e.g. Larsenn-type piles) to be checked?

For this type of work, the programme performs the geotechnical verifications, provides the stresses but does not perform the structural verifications. The section must be defined with the type Input A,E,I from ARCHIVES/SECTION ARCHIVES.

Does the software allow you to calculate the crowning kerb?

If the kerb is sufficiently rigid, it serves to ensure that the piles function as a single block, and as such, since the piles behave in the same way, assuming flat deformations, there are no stresses on the kerb itself (it is permissible to consider the kerb out of the calculation and assign, as the programme does, the minimum reinforcement in accordance with the regulations).
However, it is sometimes assumed that a post goes into failure, so that the kerb is calculated as a multi-supported beam stressed by vertical loads and loads specific to the geometry adopted (its own weight, loads on the kerb…).

Does the programme allow the verification of equilibrium of a rigid body around a point, as required by the standard?

It is possible to carry out this type of verification using the LEM method. It makes sense to consider this type of verification in the case of a free bulkhead or one constrained by a tie-rod order. Depending on the type of structure, tensioned or free, the programme chooses the point at which to refer the calculation of the equilibrium of moments and calculates the penetration depth (unknown). The calculation is already factored with an FS of 2.

Does the programme calculate the limit load, as required by the regulations?

Yes, the programme calculates the limit load, you must tick the option in the general data and indicate the reductive coefficient for the verticals under investigation.

I have a pole with a mixed section: tubular reinforcement confined by concrete, I would like to know whether the concrete is taken into account in the calculation?

Yes, the concrete liner is taken into account in the calculation

I noticed that the internal stress values are different when comparing the stress diagrams with those available on the structural analysis results window. Why?

Those shown on the structural results window refer to the individual pole, the stresses depicted on the diagrams refer to linear metres of work

I have defined a new section in the section archive, when saving the programme gives me an assignment error.

Check the name of the section, by default the programme assigns ‘-’, hyphens should be replaced with a name to be given to the section

Is it possible to define boundary conditions?

Yes, only if the FEM calculation method is chosen.

Is it possible to define layers with polylines?

No, layers must be defined by straight lines with a constant slope; the slope of the layers is assigned from the Layers window

After updating the SPW software, I cannot reopen the old project file. I realised that the file extension has changed from .spw to .spwx

With the new version of SPW, a practical converter from SPW file extensions to SPWTOTXT is also installed. To access the tool, start the software and access the main menu:

Pressing on the three dots will allow you to choose the file to be converted and once you press ‘Convert’ will generate the new converted file with the extension *.spwTotxt in the directory indicated in the box below (usually in the same directory as the file to be converted). You can change this destination manually.

Once the file has been converted, within the software, simply go to Open and select in the dialogue box that appears, the new extension and open the converted file

From the value of the active thrust coefficient provided by the programme, it appears that the slope of the upstream terrain is not taken into account

The program does not automatically calculate the calculation slope from the profile coordinates. It must be defined by the user in DATA/GEOMETRY SOIL/PROFILE CALCULATION SLOPE

I need some clarification regarding the calculation of the reaction modulus Ks, by default the programme uses Bowles' method, can I have more details?

A distinction must be made between the case where Ks is constant with depth and the case where it is variable.In the former case:

Ks=qa/unit subsidence

where qa=qult/FS

qult=limiting load

FS=safety factor (2 or 3 depending on the lithology)

In the second instead:

Ks=40*(c*Nc+0.5*gamma*B*Ngamma)+40*(gamma*Nq*Z)

Nc, Ngamma, Nq e.g. Hansen's coefficients.


Didn't find the answer? If your program has an active update plan, open a request on support.geostru.eu.