MDC¶
The full manual of MDC is here: https://help.geostru.io/mdc/en/
Why for this specific combination does the program only perform the overturning verify?¶
Each combination can be defined as: STR, GEO, EQU.
If the combination has been defined as an EQU type, the program only performs the overturning verify.
In relation to the seismic verify at overturning, does the program apply the beta parameter increase by 50%?¶
To all seismic combinations, defined by the user of EQU type, the program applies the beta increase of 50%.
Does the calculation armor provided as result by the program refer to the longitudinal development of the wall?¶
No, the armor supplied as result from the program is that referred to the meter of longitudinal retaining wall development.
Why does the software only provide limit load verification?¶
For a cellar retaining wall or a wall founded on poles the verification of overturning and sliding is omitted.
Is it possible to modulate the passive thrust?¶
Yes, it is possible to modulate it from the stratigraphy window, varying the percentage of participation in the passive thrust.
Does downstream filling contribute to passive thrust?¶
No, the downstream filling does not contributes with the passive thrust but increases the
interlocking of the foundation.
With the MDC software, is it possible to simulate a partial filling on the back of the wall?¶
Yes, just assign a value less than zero to the height of the embankment (data menu / Terrain depth).
Is it possible to assign a concentrated load on the terrain?¶
No, in MDC concentrated loads are assigned only on the section of the wall.
In MDC, is it possible to characterize a retaining wall to gravity by differentiating the base material from that wall retaining on elevation?¶
No, in MDC the foundation material cannot be differentiated.
What is the difference between evenly distributed and stripe type load?¶
In the case of a uniformly distributed load, the increase in the horizontal pressure acting on the retaining wall is constant with the depth, the intensity does not vary by varying its position. The horizontal pressure generated by a stripe type overload, on the other hand, varies with depth and position, relative to the coping of the retaining wall. The theoretical method makes use of the theory of elasticity, the applied equation is that developed by Boussinesq.
Does the MDC software execute SLE verifies?¶
Yes, the program verify on the opening of the slits and on the tensions. It is necessary to create the SLE combination, to create it access the calculation window, position the mouse cursor on the text "Load combination", from the drop-down menu that appears by clicking on the right button choose the New SLE option.
Why does the program add longitudinal reinforcing bars? The resistance check of the sections is satisfied with a lower amount of reinforcement.¶
In addition to the verification of resistance, the program checks the minimum standards normative.
The software goes error, the message is "Null overturning moment".¶
Check the value of cohesion, in the calculation of horizontal pressures the software takes into account the cohesive contribution:
sh (z) = sv (z) Ka-2cKa ^ 0.5
sh (z) = horizontal pressure
sv (z) = vertical pressure
Ka = active thrust coefficient
c = cohesion
Does the software allow verification in an undrained condition?¶
Yes, to enter the short-term parameters you need to access the stratigraphy window, set the shear resistance angle equal to zero, report the undrained cohesion on the cohesion column, report on the saturated weight on the P.U.V. column.
In the calculation the thrust, does MDC always take the friction angle between terrain and retaining wall into account?¶
The program calculates two thrusts: one in which it considers the upstream face of the wall as the thrust plane, in this case it always considers the ground-wall friction angle. The other, used for global verifies, which has as its thrust plan the ideal one that passes through the upstream extrados of the foundation; in the latter case, the program considers the ground-wall friction angle only if the "always use the wall-ground friction angle" option is checked from the Stratigraphy window.
When starting the global stability analysis, swhelope starts but the model I created does not appear.¶
Before starting the global stability analysis, make sure that you have installed Slope of the same version as the software from which the analysis starts (SPW, MDC, etc.) and enter the installation path in the global stability analysis screen.
It can sometimes happen that the PC on which the programmes are installed does not start the global stability module (SPW/Slope, MDC/Slope, etc.) correctly and therefore Slope is started normally, not reading the work. These circumstances are attributable to the machine on which the software is installed and vary from case to case (write, read permissions, incorrect uninstallation of old versions, etc.).
In any case, it is possible to overcome this problem by manually uploading the project file to Slope. In the example to be shown we will consider the global stability analysis using the software SPW - Bulkhead Design and Calculation. Once we have clicked on Run and set the Slope directory, the latter shows us the empty project screen on the screen, since for the reasons explained above, the software is started and not the global stability analysis module:


To load the job, simply go to Open and then select the *.spwtoslope file filter to open (but MDC, GDW, ESD, etc. files can be opened with the same criteria):


The file to be searched for is in the user's documents folder C:\user\Documents and, in this case, is called GlobalStabilityAnalysis.SPWTOSLOPE. To see the directory where it is saved, in the case of other software, just look at the top bar of Slope:

Once the file has been opened, the SPW design geometry file will be loaded into Slope, from which a copy can be saved.

It is recommended to save a copy of the global stability analysis file as the one opened according to the procedure just described is a temporary file, i.e. it is a file in which the last design data used by the respective source software (MDC, SPW, etc.) is saved. It is also recommended to keep the latter open while working on Slope, in order to avoid data loss
When I apply a load, a tie rod (anchor), or any other support, it seems that the software does not take it into account during the calculation.¶
Check that the combination factor for the load, tie rod, or support (SPW) is not set to zero in the load combinations.
Didn't find the answer? If your program has an active update plan, open a request on support.geostru.eu.