Pile cap¶
MP designs the single pile or micropile, or a pile cap, that is the cap and all its piles. The piles of the cap can be bored, driven or screw piles, or micropiles. The foundation type is chosen at the start: on the start screen ("Pile cap" and "Micropiles" tiles) or in General data > Foundation type.
| Single pile | Pile cap | |
|---|---|---|
| Actions | loads at the pile head | actions at the base of the column |
| Analysis | bearing capacity, settlements, structural analysis of the pile | distribution to the piles, checks of all piles and of the cap |
| File | .pmpx | .mpfx |
In pile cap projects the DATA tab shows the Pile cap group. The buttons follow the order of work: Foundation, Piles, Actions, Analyse, Results, Pile cap 3D view, Drawings, Report.
The ANALYSIS tab keeps the bearing capacity commands (Pile resistance group): code, partial factors and soil investigation verticals from which the resistances of the cap's piles are obtained. Group capacity, settlements, structural analysis and charts of the single pile are not shown, because the pile cap analysis replaces them; the Pile cap group repeats Analyse and Results. Jet grouting is not used in the pile cap.
How to start¶
From the start screen (How to start button):
- the Pile cap tile creates a cap on bored piles;
- the Micropiles tile creates a cap on micropiles (for the single micropile choose "Single pile" in General data afterwards).
The program opens in sequence General data, the pile or micropile data and the stratigraphy, then the pile cap window. If the type is changed in General data (for example from bored pile to micropile), the data window of the new type opens.
Soil¶
Stratigraphy, geotechnical properties and water table are entered as for the single pile. The pile heads are at the underside of the cap, at the depth given in Foundation.
Foundation (F6)¶
- Calculation hypothesis:
- rigid pile cap: rigid body on springs at the pile heads;
- elastic pile cap: Mindlin plate finite elements on springs at the pile heads.
- Pile layout: patterns from 1 to 9 piles with the spacings, or Free (coordinates) with the coordinates of each pile relative to the column axis. "Start from the layout" fills the table. The cap stays centred on the column: its plan dimensions come from the farthest pile in each direction, plus the edge distance.
- Geometry: thickness H, edge distance F (pile edge - cap edge), column bx x by, depth of the pile heads below ground level.
- Pile cap concrete and Pile cap reinforcement tab (materials, cover, bar diameters, maximum spacing).
If the minimum spacing between piles is less than 2.5 D a warning appears: with piles so close the group efficiency is reduced.
Piles¶
- Project pile: type, diameter, length, materials and reinforcement are those of the MP pile ("Pile data...") and apply to all the piles of the cap.
- Screw piles: with the Screw type and the helices assigned in Pile data, the helices are shown in the 3D view, in the drawing and in the layout section.
- Head stiffnesses: axial with Randolph and Wroth, lateral from the pile on Winkler springs with the subgrade modulus of the structural analysis, torsional Kt. The head is fixed in the cap, or pinned if so set in General data. The stiffnesses can be entered by hand.
- Design resistances of the single pile: recalculated at every analysis from the MP bearing capacity, with the
code, the partial factors and the investigation verticals of ANALYSIS > Bearing capacity, and with the head at the
underside of the cap.
- Compression and tension come from the bearing capacity.
- The horizontal resistance comes from Broms and needs the ultimate moment of the pile in Pile data.
- The resistances can also be entered by hand.
- Below the resistances a line shows how the compression Rd is obtained: Rd = Rk,p/γb + Rk,s/γs - Wp, with the head level and the length used. Rd differs from ANALYSIS > Bearing capacity because there the head is at ground level, with the pile projection, while in the pile cap it is at the underside of the cap and the projection is 0.
- Group efficiency Ev, Eh: "Estimate Ev" applies Converse-Labarre to the pile layout. It is an estimate for cohesive soils; in granular soils it can be left at 1.
Pile cap on micropiles¶
With the Micropile type in General data the piles of the cap are micropiles, all equal to the project micropile (Micropile data button):
- drilling diameter Dp, length of the shaft and of the bulb, bulb expansion factor alpha (bulb diameter = alpha x Dp; alpha is never less than 1);
- reinforcement with a tube or with bars, grouting and bearing capacity method of the micropiles.
Compared with piles:
- the axial stiffness EA comes from the reinforcement and the grout, the bending stiffness EI from the reinforcement only;
- the resistances come from the micropile bearing capacity;
- the structural check uses the section of the tube or of the bars;
- the 3D view shows bulb and tube, the drawings the typical micropile, the report the micropile table.
Actions¶
Actions are given at the base of the column (top of the cap): N positive downwards, moments as vectors with the right-hand rule, Tx and Ty at the top of the cap. Mz is the torque about the vertical axis, positive anticlockwise seen from above: the piles carry it with horizontal forces proportional to the distance from the centre of the pile group and with the torque at the head Mt = Kt rz. The sketch in the Actions window shows the positive directions. There are two ways.
- Assigned combinations: each combination has a type (ULS, SLS characteristic, frequent, quasi-permanent, SLV seismic). They can be imported from Excel.
- Load cases: enter G1, G2, the variable actions Q with the category of table 2.5.I of NTC 2018 (the psi factors
are filled in automatically) and the earthquake Ex, Ey. The program generates the NTC 2018 combinations:
- ULS (A1) with unfavourable (1.3 / 1.5) and favourable (1.0 / 0.8) permanent actions;
- SLS characteristic, frequent and quasi-permanent;
- SLV with the 30% rule (±Ex ±0.3 Ey, ±0.3 Ex ±Ey).
Each variable action is in turn the leading one. Cases with the same group (for example wind +X and wind -X) are alternatives: they never enter the same combination.
Analysis¶
"Analyse" performs in sequence:
- stiffnesses and resistances from the pile and the soil (unless entered by hand);
- the distribution of the actions to each pile, in each combination (N, T, M and torque Mt at the head);
- the geotechnical checks of each pile in the ULS and SLV combinations (compression, tension, horizontal) and of the group (Ev, Eh);
- the structural check of the critical piles of each ultimate combination (maximum N, minimum N, maximum T): pile on springs with N and T at the head and the head fixed in the cap, then the section check as in the Structural analysis. If more bars than those assigned are needed a warning appears. The torque Mt is reported, but the torsion check of the pile is not performed;
- bending and shear of the cap: sections at the column faces, as wide as the cap, with the reduction
beta = av/2d for piles within 2d of the face. Without negative moment the top bars are a fraction of the bottom
ones (25% by default, in Pile cap reinforcement). The method follows the structural code of General data:
- NTC 2008 and NTC 2018: GeoStru solver of rectangular sections (parabola-rectangle concrete, ULS domain, SLV combinations at first yielding as required by NTC 7.2.5 for foundations, shear NTC 4.1.2.3.5.1);
- Eurocodes: EC2 formulas (rectangular stress block, shear EC2 6.2.2);
- the strut-and-tie model (EC2 6.5, NTC 2018 4.1.2.3.7), if the cap is deep (cot theta <= 2 for all piles, that
is theta >= 26.6 degrees):
- the column load, split into quarters at b/4 from the axis, goes down with a strut to each compressed pile; lever arm z = 0.9 d;
- ties along x and y: T = sum of N l / z over the piles of one side, and the bottom bars also cover the tie;
- column bearing as a concentrated load (EC2 6.7): N/Ac0 <= fcd (Ac1/Ac0)^0.5 <= 3 fcd;
- node above the pile (CCT): pile reaction and strut <= 0.85 nu' fcd, with nu' = 1 - fck/250;
- punching shear (EC2 6.4, NTC 2018 4.1.2.3.5.4):
- column at the face, against vRd,max;
- column on the control perimeter, up to the nearest pile, with vRd,c increased by 2d/a;
- most loaded pile, with the perimeter at 2d cut by the edges of the cap;
- the settlements in the SLS combinations:
- maximum, differential and angular distortion between piles;
- estimate of the group settlement with Rs = n^0.5 (Fleming et al., 1992).
With a rigid cap, fixed heads and soft soil, part of the overturning is carried by the moments at the pile heads. For this reason the axial force in the piles is lower than with the classic formula N/n ± M·x/Σx². With pinned heads the analysis matches the classic formula.
Results¶
Above the tabs a highlighted line shows the total bearing capacity of the pile group, Rd = n · Ev · Rd,c, with the maximum total load on the piles in the ultimate combinations, and the total settlement of the group in the SLS combinations (maximum pile settlement times Rs = n^0.5). The bearing of the cap on the soil is not counted, on the safe side.
- Layout: plan with the pile actions of the selected combination. With the rigid cap a box above the plan recalls it.
- Pile actions: N, T, M, Mt and settlement of each pile, plus the summary of the checks.
- Pile checks: Ed/Rd ratios and structural check, coloured (green up to 0.8, orange up to 1, red above). The outcome says what is not verified. All cases or only the worst one of each pile can be shown. Clicking a row shows that combination in the other tabs.
-
Deformed shape and stresses:
- 2D view: plan of the cap coloured by the quantity chosen in Colours (settlement, moments mx and my, twisting moment mxy, stresses sigma x and sigma y at the bottom face, maximum principal stress at the bottom and top faces, von Mises equivalent stress) and the deformed Section along a row of piles, with the stresses through the cap thickness and the moment along the piles;
- 3D view: deformed cap and piles;
- Deformation scale automatic or chosen (from x 10 to x 10000).
Plate moments and stresses are calculated only with the elastic cap; with the rigid cap the deformed shape and the displacements are shown. - Pile cap reinforcement. - 3D view, with the most compressed pile in red. The Pile reactions layer is off when the view opens and can be switched on from the layer list; layers stay on or off when the combination changes.
Drawings and report¶
- Drawings:
- pile cap sheet: dimensioned plan with numbered piles, sections A-A and B-B with the reinforcement, bar schedule;
- cage of the typical pile, with the bars and links of the pile checks, or the typical micropile;
- exported to DXF like the other drawings.
- Report: project data, geometry and pile coordinates, stiffnesses and resistances, load cases and combinations, distribution, geotechnical and structural checks of the piles, reinforcement, shear and punching, settlements, summary.
Trial version¶
In the trial version the whole pile cap workflow can be tried (data, analysis, layout, 3D view, deformed shape), but the result values cannot be read:
- the Pile actions, Pile checks and Pile cap reinforcement tabs are covered;
- layout and 3D view show the geometry without the pile actions;
- the deformed shape shows shapes and colours without legends and values;
- the report is not generated.
Examples¶
In the Examples folder (also from the start screen):
- Plinto 4 pali - rigido: rigid cap with 4 piles, assigned combinations;
- Plinto 9 pali - elastico: elastic cap with 9 piles, load cases with generated combinations, alternative wind;
- Plinto 3 pali - disposizione libera: 3 piles, free layout with coordinates;
- Plinto 6 pali - sisma: 6 piles, load cases with earthquake along x and y.
©Geostru