Skip to content

Settlement check (Ed ≤ Cd)

The check compares the settlements computed for the service combinations (Ed) with the limit values set by the designer (Cd). It is opened from the calculation tab, settlements group, with the Settlement check (Ed ≤ Cd) button. The stratigraphy and the foundation must be defined.

Code references:

Code Serviceability limit state Damage limitation state (seismic)
EN 1997-1 / EN 1998-5 par. 6.6 and Annex H EN 1998-5
NTC 2018 (Italy) par. 6.4.2.2 par. 7.11.5.3.2

The codes do not give numerical values for Cd: the designer sets them according to the superstructure. The window nevertheless offers reference values from the literature (see below).

Combinations considered

All load combinations of type Service are checked:

  • SLS (serviceability limit state): service combination without seismic correction;
  • DLS (damage limitation state): service combination with the seismic correction active.

To run the DLS check, add in Load combinations a Service combination with the loads of the seismic service combination and the seismic correction switched on.

Settlement calculation

For each combination the program computes the elastic settlements (Steinbrenner) at the centre and at the corner of the foundation, with the combination pressure net of the weight of the excavated soil. Young's modulus E, Poisson's ratio, bedrock depth and compressible layer thickness are those of the Elastic settlements window; if not assigned, those of the foundation layer are used.

From the two values:

\[ \Delta w = \left| w_{centre} - w_{corner} \right| \qquad \beta = \frac{\Delta w}{d} \qquad d = \frac{\sqrt{B^2 + L^2}}{2} \]

where \( \Delta w \) is the differential settlement, \( \beta \) the angular distortion and \( d \) the distance between the centre and the corner of the foundation.

Angular distortion

The angular distortion is the ratio between the differential settlement of two points and their distance. It is expressed as 1/n: in the limit field enter n (for 1/500 enter 500). Indicative values: 1/500 no cracking in buildings, 1/300 first cracks in infill walls, 1/150 structural damage (Skempton and MacDonald, Bjerrum, EN 1997-1 Annex H).

Limits (Cd)

For SLS and DLS the following are assigned:

Limit Unit
Maximum allowable settlement mm
Allowable differential settlement mm
Allowable angular distortion n of 1/n

An empty field or 0 means no limit assigned: that check is not performed.

Reference values

The Reference values menu fills in the limits with values from the literature. They remain editable and must be adapted to the structure.

Reference Maximum settlement Differential Distortion SLS / DLS
EN 1997-1 Annex H, ordinary structures on isolated foundations 50 mm – 1/500 / 1/300
Skempton and MacDonald (1956), isolated footings on sand 40 mm 25 mm 1/500 / 1/300
Skempton and MacDonald (1956), isolated footings on clay 65 mm 40 mm 1/500 / 1/300
Skempton and MacDonald (1956), rafts on sand 65 mm 25 mm 1/500 / 1/300
Skempton and MacDonald (1956), rafts on clay 100 mm 40 mm 1/500 / 1/300

For the DLS the distortion is set to 1/300, the threshold of the first cracks.

Results

The Calculate button updates the table: for each combination it shows limit state, pressure, settlement at centre and at corner, differential settlement, angular distortion and result. The combination is Satisfied if it meets all the assigned limits; values beyond the limit are shown in red.

With OK the limits are saved in the project. If at least one limit is assigned, the calculation report contains the section Settlement check (Ed ≤ Cd) with the code reference, the elastic parameters, the table of limits and the table of results.

Layered soils

The elastic method uses a single modulus E. For strongly layered soils compare the settlements with those of the oedometric method.

© GeoStru